Specializing in the sales, service and installation of petroleum equipment
Tank level
monitors
                   

INT750P/3S

  INCON TANK SENTINEL (TS-750) —
•Fixed feature, third-party approved
  volumetric leak detection.
•Complete, cost-effective compliance kit
  monitors up to four tank level probes and
  up to eight leak sensors.
•Console includes alpha-numeric LCD display
  (two lines x 40 characters) and 24 column
  thermal printer.
•Optional SCALD feature (Statistical   Continuous Automatic Leak Detection)
  provides continuous leak testing software
  for 'Open 24-hours' operations.
•Level units can be inches or centimeters,
  volume units gallons or liters and temperature
  units Fahrenheit or Celsius.
 

MODEL
INT750P/1
INT750P/1S

INT750P/2
INT750P/2S

INT750P/3
INT750P/3S

INT750P/4
INT750P/4S

DESCRIPTION
Tank monitor, 1 tank/8 sensor
Tank monitor, 1 tank/8 sensor,
w/SCALD
Tank monitor, 2 tank/8 sensor
Tank monitor, 2 tank/8 sensor,
w/SCALD
Tank monitor, 3 tank/8 sensor
Tank monitor, 3 tank/8 sensor,
w/SCALD
Tank monitor, 4 tank/8 sensor
Tank monitor, 4 tank/8 sensor,
w/SCALD

DOCS
Features

Install/Ops
Inquiries?
Call us 8am-5pm
Pacific time, or
email us.
  
               

INT5D
  INCON TANK SENTINEL (TS-5) —
•Automatic tank gauging system with third-
  party approved volumetric leak detection.
•Monitors up to 12 tank level probes.
•Standard models include two input only
  channels, two output only channels.
•Console includes touch screen LCD display
  (320 x 240 pixels).
•Standard communications ports include
  ethernet, 2x RS-232 and USB.

•Optional SCALD feature (Statistical
  Continuous Automatic Leak Detection)
  provides continuous leak testing software for
  'Open 24-hours' operations.
•Internal fax and data modems available as
  options.
•Can provide dispenser information and
  automate reconciliation when used in
  conjunction with Incon's Dispenser Interface
  Module.
 

MODEL
T5D

Hardware opts
INTS-DIMIBS
INTS-LONS
INTS-MDMIB

Software opts
INTS-TT
INTS-TRAC


DESCRIPTION
Tank monitor, 12 tank, 120v


Hardware, dispenser i/f (less cable)
Module, EcheLON comm (IFSF)
Modem, internal fax/data


SCALD, 24 hr continuous testing
Reconciliation and auto calibration

DOCS
Features

Install/Ops
 
               

INT550D
 

INCON TANK SENTINEL (TS-550) —
•Automatic tank gauging system with third-
  party approved volumetric leak detection.
•Monitors up to 36 tank level probes.
•Monitors up to 36 two wire leak sensors.
•Modular design provides flexibility and
  
customization of the system.
•Six total modules can be installed inside the
  TS-550 (a maximum of four intrinsically safe
  modules and a maximum of three of any one
  kind of module.
•Standard communications ports include
  ethernet, 2x RS-232 and USB.

•Console includes options for a touch screen
  LCD display (320 x 240 pixels) and printer.
•Optional SCALD feature (Statistical
  Continuous Automatic Leak Detection)
  provides continuous leak testing software for
  'Open 24-hours' operations.
•Internal fax and data modems available as
  options.

 

MODEL
T550

T550D

T550DP


Hardware opts
INTS-DIMIBS
INTS-LONS
INTS-MDMIB

Software opts
INTS-TT
INTS-TRAC
INTS-ELLD
INTS-VRM
INTS-SCM

Intrinsically safe
i/f modules

INTS-PRB
INTS-2WSNS
INTS-3WSNS
INTS-420IB

Non-intrinsic
safe i/f modules

INTS-ACI
INTS-RLY
INTS-10ARLY
INTS-IO

INTS-420EXP

DESCRIPTION
Tank monitor, 36 tank, no display
or printer
Tank monitor, 36 tank w/display,
no printer
Tank monitor, 36 tank, w/display
and printer


Hardware, dispenser i/f (less cable)
Module, EcheLON comm (IFSF)
Modem, internal fax/data


SCALD, 24 hr continuous testing
Reconciliation and auto calibration
Leak detection, electronic line
Monitoring, vapor recovery
Monitoring, secondary containment



Module, LL2 probe, 12 input
Module, 2-wire sensor, 12 input
Module, 3-wire sensor, 8 input
Module, 4-20mA, 8 input



Module, AC input, disp hook, 12 in
Module, relay output, 8 output
Module, 10 amp relay, 6 output
Module, 4 output 4-20mA, 8 input
3-240vac/dc
Module, 4-20mA, 8 input

DOCS
Features

 
               

INT5000DP
  INCON TANK SENTINEL (TS-5000) —
•Automatic tank gauging system with
  third-party approved volumetric leak
  detection.
•Monitors up to 72 tank level probes.
•Monitors up to 72 2-wire leak sensors.
•Modular design provides flexibility and
  customization of the system.
•Six total modules can be installed
  inside the TS-5000 (a maximum of four
  intrinsically safe modules and a
  maximum of three of any one kind of
  module.
•Standard communications ports include
  ethernet, 2x RS-232 and USB.

•Console includes options for a touch
  screen LCD display (320x240 pixels)
  and printer.
•Optional SCALD feature (Statistical
  Continuous Automatic Leak Detection)
  provides continuous leak testing soft-
  ware for 'Open 24-hours' operations.
•Internal fax and data modems available
  as options.
 

MODEL
T5000

T5000D

T5000DP


Hardware opts
INTS-DIMIBS
INTS-LONS
INTS-MDMIB

Software opts
INTS-TT
INTS-TRAC
INTS-ELLD
INTS-VRM
INTS-SCM

Intrinsically safe
i/f modules

INTS-PRB
INTS-2WSNS
INTS-3WSNS
INTS-420IB

Non-intrinsic
safe i/f modules

INTS-ACI
INTS-RLY
INTS-10ARLY
INTS-IO

INTS-420EXP

DESCRIPTION
Tank monitor, 72 tank, no display
or printer
Tank monitor, 72 tank w/display,
no printer
Tank monitor, 72 tank, w/display
and printer


Hardware, dispenser i/f (less cable)
Module, EcheLON comm (IFSF)
Modem, internal fax/data


SCALD, 24 hr continuous testing
Reconciliation and auto calibration
Leak detection, electronic line
Monitoring, vapor recovery
Monitoring, secondary containment



Module, LL2 probe, 12 input
Module, 2-wire sensor, 12 input
Module, 3-wire sensor, 8 input
Module, 4-20mA, 8 input



Module, AC input, disp hook, 12 in
Module, relay output, 8 output
Module, 10 amp relay, 6 output
Module, 4 output 4-20mA, 8 input
3-240vac/dc
Module, 4-20mA, 8 input

DOCS
Features
 
               

INTS2001, TS1001
  INCON TANK SENTINEL (TS-1001/2001) —
•Third-party approved volumetric leak
  detection.
•Monitors up to four tank level probes
  TS-1001 series) or eight tank level
  probes (TS-2001 series).
•Standard models include two input
  only channels, two output only chan-
  nels and 12 (in the 1001 series) or 24
  (2001 series) sensor inputs. All are
  expandable via options.
•Console includes alpha-numeric LCD
  display (two lines x 40 characters) and
  24 column thermal printer.
•Optional SCALD feature (Statistical
  Continuous Automatic Leak Detection)
  provides continuous leak testing soft-
  ware for 'Open 24-hours' operations.
•Level units can be inches or centimeters,
  volume units gallons or liters and
  temperature units Fahrenheit or Celsius.
 

MODEL
INTS-1001/2P
INTS-1001/4P
INTS-2001/8P

DESCRIPTION
Tank monitor, 2 tank/12 sensor
Tank monitor, 4 tank/12 sensor
Tank monitor, 8 tank, 24 sensor


DOCS
Features

Install/Ops
 
               




INTS-LLD








AutoLearn™











POWER
SENTINEL












INTS-DIM










INTS-TIP

 

INCON ACCESSORIES —
Probes, accessories, interface, software.


LEAK DETECTION & INVENTORY CONTROL
PROBES — Magnetostrictive position
measurement technology is used to accurately
report inventory levels in tanks. Two versions
are available: TSP-LL2 (for underground tank
and petroleum applications) and LL2-I (for
aboveground tanks, chemical or oil waste and
inventory-only applications.


FLOAT KITS — Each float kit includes a product
and a water float, constructed of a Nitrile
rubber water float containing a nickel-plated
ballast compatible with a wide variety of
petroleum products. Available in 2", 3" and
4". Product specific.


INSTALLATION KITS — Used with LL2 probes
in underground tank applications.

ELECTRONIC LINE LEAK DETECTION —
LINE SENTINEL™ utilizes patented flow-based
  technology to perform multiple line tightness
  tests. It performs positive shutdown if a leak
  is detected.
Its wireless, low-cost installation
  retrofits easily into existing submersible pump
  housings.

TS-LS500 AUTOLEARN™ provides automatic
  3.0gph hourly, 0.2gph monthly and 0.1gph
  annual precision line leak detection for the
  TS-550 and TS-5000 models.
  The following must be ordered and installed
  in the tank monitor console when using the
  AutoLearn option: the TS-4201B or TS-420EXP
  module, the TS-ACI and TS-RLY modules, and
  the TS-ELLD software option. If the TS-TPI
  turbine pump communications interface is
  in place, the TS-RLY is not necessary, though
  FE Petro intelligent controllers would be
  necessary.

SENSORS — Both discriminating and non-
discriminating sensors are available, based on
your specific application. The TSP-ULS sensor
is a good 'all purpose' non-discriminating
choice for sumps, dispenser pans and the
interstitial space on doublewall steel tanks.

EXTERNAL CONSOLE HARDWARE —
DISPENSER INTERFACE MODULE collects
  information on all dispensed product and
  consolidates the data into a concise, easy-
  to-read format. Calculates the quantity of
  product dispensed from each fueling point.
TURBINE PUMP INTERFACE provides a
  communications link for FE Petroleum
  intelligent pump controllers to communicate
  faults to enabled devices. Integrating the
  intelligence of those two systems enables a
  station pumping fuel without service calls
  during several events that would normally
  result in down time and lost sales. Not
  available with the TS-750.

POWER SENTINEL™ — Provides power protection
for all equipment at a site. Connects to the
electrical power panel via conduit and a
dedicated circuit breaker. NEMA-12 rated
enclosure in moisture, dust and tamper-resistant.
The Power Sentinel establishes power quality
before it gets to the main breaker...allowing
the entire site to benefit from clean power. It
protects the entire site from power surges and
achieves power factor correction, which can
lower demand charges and motor operating
temperatures, helping to prolong life of your
electrical equipment.

 

MODEL
Probes
INTSPLL2-65
INTSPLL2-69
INTSPLL2-81
INTSPLL2-101
INTSPLL2-125
INTSPLL2-137
INTSPLL2-149

Probe float kits
INTSP-IDF2
INTSP-IDF4
INTSP-IGF2
INTSP-IGF4

Installation kits
INTSP-K2A
INTSP-K4A

Site software
INSS-SU5
INSS-SU20
INSS-SU100

Internal Software
INTS-SCALD
INTS-DOM2
INTS-FM2
INTS-LLDI
INTSReconciliation

Leak detection
INTS-LLD/FE

INTS-LLD/RJ

INTS-LLD-RJQ

TS-LS500
Autolearn™
INTS-LS500/2
INTS-LS500/3
INTS-LS500/4

INTS-LS500E/2
INTS-LS500E/3
INTS-LS500E/4

High level switch
INTSP-HLS

Non-discrim
sensors

INTSP-EIS
INTSP-ULS

Discriminating
sensors

INTSP-DDS
INTSP-DIS
INTSP-DMS
INTSP-DTS
INTSP-DVS
INTSP-HIS
INTSP-MWS

Sensor inst kits
INTSP-KI2
IN TSP-K5

Dispenser interface
TS-DIMIB
TSP-WDCBL
TSP-TDCBL
TSP-GDCBL
TSP-GSDCBL

DESCRIPTION

Probe, liquid level, for 5' dia
Probe, liquid level, for 5'4" dia
Probe, liquid level, for 6'4" dia
Probe, liquid level, for 8' dia
Probe, liquid level, for 10' dia
Probe, liquid level, for 11' dia
Probe, liquid level, for 12' dia


Float kit, 2", for diesel
Float kit, 4", for diesel
Float kit, 2", for gasoline
Float kit, 4", for gasoline


Probe installation kit, 2" riser
Probe installation kit, 4" riser


Site Sentinel software, 1-5 sites
Site Sentinel software, 1-20 sites
Site Sentinel software, 1-100 sites


24-hr continuous tank test
Data only modem
Fax & data modem
LLD interface
Dispenser reconciliation


Detector, line leak w/FE Petro
adapter
Detector, line leak w/Red Jacket
adapter
Detector, line leak w/Red Jacket
Quantum adapter


Kit, transducer, 2 line, intrinsic
Kit, transducer, 3 line, intrinsic
Kit, transducer, 4 line, intrinsic

Kit, transducer, 2 line, non-intrinsic
Kit, transducer, 3 line, non-intrinsic
Kit, transducer, 4 line, non-intrinsic


Switch, hi level, adj



Sensor, liquid, electro-optic
Sensor, liquid, float switch



Sensor, dispenser sump
Sensor, interstitial
Sensor, sump, magnetostrictive
Sensor, turbine sump
Sensor, vapor only
Sensor, brine-fill interstice
Sensor, monitor well


Kit, interstitial, 2" riser cap
Kit, unistrut, TSP-DDS/TSP-DTS



Module, interface (less cable)
Cable, Wayne DIM
Cable, Tokheim DIM
Cable, Gilbarco DIM
Cable, Gilbarco 'G-Site' DIM

DOCS
Probes
Level probes
Float kits
Install kit

Sensors
TSP-DDS
TSP-DIS
TSP-DMS
TSP-DTS
TSP-DVS
TSP-EIS
TSP-HIS
TSP-HLS
TSP-MWS
TSP-ULS


Leak Detect
TS-LLD
TS-LS300

Interface
TS-DIM
TS-TPI

Remote Alarm
TS-RA2
TS-RK

 

©2009 Mascott Equipment Co